Functionalities:
- Operation on wide range of 3 phase AC input voltages
- Master-Slave operation up to 900kW
- Large user display, menu-driven operation
- EMC surpasses CE requirements: low emission and high immunity
- Low audible noise: temperature controlled cooling fans
*Included*
- Ethernet interface, built-in sequencer and web interface
- Simulation software: Leadless sensing, Internal resistance and Photovoltaic simulation
- Durable digital encoders for voltage and current adjustment and menu operation
Specifications:
- Input voltage (3 phase) : 342-528 V AC (48-62 Hz)
- Active Power Factor Correction (PFC) : up to 0.996 (at 100% load)
- Efficiency (sink & source mode) : up to 96% (at full load)
- Output ripple and spikes : from 10 mv rms / 55 mV pp
- Regulation : from 2 mV (0-100% load step)
- Recovery time : from 100 µs (50-100% load step)
- Programming speed : from 1.5 ms (10-90%)
- Output voltage and current stability : 50.10-6 / 80.10-6
- MTBF : 500.000 hrs
- Operating ambient temperature : -20 to +50 ºC
Standards:
- Power supply standard : EN 61204-3
- Generic Emission : EN 61326-1 (class B equipment, for use in domestic establishment)
- Generic Immunity : EN 61326-1 (equipment for use in industrial and domestic establishment)
- Safety : EN 60950 / EN 61010
- Insulation input / output : 3750 V rms
- Protection class : IP20
Dimensions and weight:
- Width = 19
- Height = 3 U
- Depth = 591 mm
- Weight = 27 kg
Options for SM15K series
Interfaces for SM15K series
- INT MOD CON (Isolated Contacts)
- INT MOD SER (Interface serial)
- INT MOD DIG (Digital I/O)
- INT MOD ANA (Interface analog)
- INT MOD M/S 2 (Master/Slave Interface 2)
(generation 2 Master/Slave Interface, SM15K only)
SM15K Master/Slave parallel connection sets
For models:
SM500-CP-90, SM1500-CP-30 & SM210-CP-150
- M/S PAR SET C2 (2 units in parallel)
- M/S PAR SET C3 (3 units in parallel)
- M/S PAR SET C4 (4 units in parallel)
- M/S PAR SET C5 (5 units in parallel)
- M/S PAR SET C6 (6 units in parallel)
- M/S PAR SET C7 (7 units in parallel)
- M/S PAR SET C8 (8 units in parallel)
- M/S PAR SET C9 (9 units in parallel)
- M/S PAR SET C10 (10 units in parallel)
- M/S PAR SET C11 (11 units in parallel)
- M/S PAR SET C12 (12 units in parallel)
For model:
SM70-CP-450 (only)
- M/S PAR SET A2 (2 units in parallel)
- M/S PAR SET A3 (3 units in parallel)
- M/S PAR SET A4 (4 units in parallel)
- M/S PAR SET A5 (5 units in parallel)
- M/S PAR SET A6 (6 units in parallel)
SM15K Master/Slave series connection sets
For model:
SM500-CP-90 (only)
- M/S SER SET BA (base set for 2 units in series)
- M/S SER SET BB (extension set for 3-6 units in series)
Example:
- 2 units in series = 1x BA
- 3 units in series = 1x BA, 1x BB
- 4 units in series = 1x BA, 2x BB
- 5 units in series = 1x BA, 3x BB
- 6 units in series = 1x BA, 4x BB