Functionalities:
- Master / Slave parallel and series operation with voltage and current sharing
- Stacking is allowed, space between units is not required
- High power system configuration from multiple units
- 19” rack mounting or laboratory use (feet included)
- Remote sensing
- Interlock
Specifications:
- Input voltage (3 phase, rated voltage range) : 342 – 528 V AC, Vnom line to line (48-62 Hz)
- Active Power Factor Correction (PFC) : 0.98 (at 100% load)
- Efficiency : up to 90% (at full load)
- Output ripple and spikes : from 0.8 mVrms / 10 mVpp
- Regulation : from 2.5 mV (0-100% load step)
- Recovery time : from 100 μs (50-100% load step)
- Programming speed : from 2.7 ms (10-90%), optional from 0.4 ms
- Analog programming accuracy : from 0.2%
- Output voltage and current stability : 5.10-5 / 10.10-5
- MTBF : 500.000 hrs
- Operating ambient temperature : -20 to +50 °C
Standards:
- Power supply standard : EN 61204-3
- Generic Emission : EN 61326-1 (class B equipment, for use in domestic establishment)
- Generic Immunity : EN 61326-1 (equipment for use in industrial and domestic establishment)
- Safety : EN 60950 / EN 61010
- Insulation input / output : 3750 Vrms
- Protection class : IP20
- cTÜVus
Dimensions and weight:
- Width = 19
- Height = 4 U
- Depth = 542 mm
- Weight = 27 kg
Options for SM6000 series
- P220 : Potentiometers repl. with encoders
Interfaces for SM6000 series
- P157 : PSC-ETH built-in
(not for SM300-20 and SM600-10, for these units please use the external PSC-ETH Module, price on page 3)
- P155 : PSC-232 built-in
- P277 : PSC-PB built-in
- P278 : PSC-CAN built-in
- P156 : PSC-488 built-in
- P154 : ISO AMP CARD built-in
High speed programming options SM6000 series
- P166 : for SM 15-400
- P167 : for SM 30-200
- P168 :for SM 45-140
- P169 : for SM 60-100
- P170 : for SM 70-90
- P171 : for SM 120-50
- P172 : for SM 300-20
- P270 : for SM 600-10
Power sink options SM6000 series
- P230 : for SM 15-400
- P231 : for SM 30-200
- P232 : for SM 45-140
- P233 : for SM 60-100
- P234 : for SM 70-90